¡Hola! Acceder o Registrarse
APP Manual de datos Transmisión en vivo 290K likes UtsourceComprar(0)
Pida su cotización(0)
Dear customers, due to the implementation of the GDPR policy in Europe, UTSOURCE has also made adjustment accordingly to meet the policy requirements. Please read the new privacy policy carefully and this window will no longer pop up after you accept it.
Delivery Address
+ Añadir dirección
Nueva dirección de transporte
* Por favor, complete el número de teléfono celular correctamente para asegurarse de que puede recibir la información de seguimiento a tiempo.
Código de país
Favorita
Utsource certified used parts
Las piezas usadas certificadas por Utsource ofrecen las siguientes garantías:
1. Utsource inspeccionará los productos, incluida la inspección de apariencia (sin daños serios en la apariencia), seleccionará proveedores calificados y honestos, y asegurará una tasa de calificación del 98%.
2. Algunas partes son probadas por la máquina.
3. Las piezas certificadas de Utsource pueden devolverse y reembolsarse incondicionalmente dentro de los 60 días.
Descripción de producto
The AD594/AD595 is a complete instrumentation amplifier and thermocouple cold junction compensator on a monolithic chip. It combines an ice point reference with a precalibrated amplifier to produce a high level (10 mV/°C) output directly from a thermocouple signal. Pin-strapping options allow it to be used as a linear amplifier-compensator or as a switched output setpoint controller using either fixed or remote setpoint control. It can be used to amplify its compensation voltage directly, thereby converting it to a stand-alone Celsius transducer with a low impedance voltage output. The AD594/AD595 includes a thermocouple failure alarm that indicates if one or both thermocouple leads become open. The alarm output has a flexible format which includes TTL drive capability. The AD594/AD595 can be powered from a single ended supply (including +5 V) and by including a negative supply, temperatures below 0°C can be measured. To minimize self-heating, an unloaded AD594/AD595 will typically operate with a total supply current 160 μA, but is also capable of delivering in excess of ±5 mA to a load. The AD594 is precalibrated by laser wafer trimming to match the characteristic of type J (iron-constantan) thermocouples and the AD595 is laser trimmed for type K (chromel-alumel) inputs. The temperature transducer voltages and gain control resistors are available at the package pins so that the circuit can be recalibrated for the thermocouple types by the addition of two or three resistors. These terminals also allow more precise calibration for both thermocouple and thermometer applications. The AD594/AD595 is available in two performance grades. The C and the A versions have calibration accuracies of ±1°C and ±3°C, respectively. Both are designed to be used from 0°C to +50°C, and are available in 14-pin, hermetically sealed, side-brazed ceramic DIPs as well as low cost cerdip packages.
Todos los nombres de productos, marcas registradas, marcas y logotipos utilizados en este sitio son propiedad de sus respectivos dueños. La representación, descripción o venta de productos con estos nombres, marcas comerciales, marcas y logotipos es solo para fines de identificación y no pretende indicar ninguna afiliación o autorización por parte de ningún titular de derechos.
Vista previa de las 3 primeras páginas de la ficha técnica
Vista previa del documento
Type K (AD595) Thermocouples Can Be Used with Type T Thermocouple Inputs Low Impedance Voltage Output: 10 mV/C Built-In Ice Point Compensation Wide Power Supply Range: 15 V Low Power: <1 mW typical Thermocouple Failure Alarm Laser Wafer Trimmed to 1C Calibration Accuracy Setpoint Mode Operation Self-Contained Celsius Thermometer Operation High Impedance Differential Input Side-Brazed DIP or Low Cost Cerdip
PRODUCT DESCRIPTION The is a complete instrumentation amplifier and thermocouple cold junction compensator on a monolithic chip. It combines an ice point reference with a precalibrated amplifier to produce a high level (10 mV/°C) output directly from a thermocouple signal. Pin-strapping options allow to be used as a linear amplifier-compensator as a switched output setpoint controller using either fixed or remote setpoint control. It can be used to amplify its compensation voltage directly, thereby converting to a stand-alone Celsius transducer with a low impedance voltage output.
The AD594/AD595 includes a thermocouple failure alarm that indicates if one or both thermocouple leads become open. The alarm output has a flexible format which includes TTL drive capability.
The AD594/AD595 can be powered from a single ended supply (including +5 V) and by including a negative supply, temperatures below 0°C can be measured. To minimize self-heating, an unloaded AD594/AD595 will typically operate with a total supply current 160 µA, but is also capable of delivering in excess to a load.
The AD594 is precalibrated by laser wafer trimming to match the characteristic of type J (iron-constantan) thermocouples and the AD595 is laser trimmed for type K (chromel-alumel) inputs. The temperature transducer voltages and gain control resistors
are available at the package pins so that the circuit can be recalibrated for the thermocouple types by the addition of two or three resistors. These terminals also allow more precise calibration for both thermocouple and thermometer applications.
The AD594/AD595 is available in two performance grades. The C and the A versions have calibration accuracies ± 1°C and ± 3°C, respectively. Both are designed to be used from to +50°C, and are available in 14-pin, hermetically sealed, sidebrazed ceramic DIPs as well as low cost cerdip packages.
PRODUCT HIGHLIGHTS 1. The AD594/AD595 provides cold junction compensation,2. Compensation, zero, and scale factor are all precalibrated by laser wafer trimming (LWT) of each IC chip.
3. Flexible pinout provides for operation as a setpoint controller or a stand-alone temperature transducer calibrated in degrees Celsius.
4. Operation at remote application sites is facilitated by low quiescent current and a wide supply voltage range V to dual supplies spanning 30 V.
5. Differential input rejects common-mode noise voltage on the thermocouple leads.Information furnished by Analog Devices is believed to be accurate and reliable. However, no responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Analog Devices.
AD594/AD595SPECIFICATIONS +25C and 5 V, Type J (AD594), Type K (AD595) Thermocouple, unless otherwise noted)
ABSOLUTE MAXIMUM RATING +VS to VS Common-Mode Input Voltage Differential Input Voltage Alarm Voltages +ALM ALM Operating Temperature Range Output Short Circuit to Common
AMPLIFIER CHARACTERISTICS Closed Loop Gain3 Input Offset VoltageInput Bias Current Differential Input Range Common-Mode Range Common-Mode Sensitivity RTO Power Supply Sensitivity RTO Output Voltage Range
Dual Supply Single Supply Usable Output 3 dB BandwidthALARM CHARACTERISTICS VCE(SAT) 2 mA Leakage Current Operating Voltage at ALM Short Circuit Current
POWER REQUIREMENTS Specified Performance Operating5 Quiescent Current (No Load) +VS VSNOTES 1Calibrated for minimum error at +25°C using a thermocouple sensitivity of 51.7 µV/°C. Since a J type thermocouple deviates from this straight line approximation, the AD594 will normally read 3.1 mV when the measuring junction at 0°C. The AD595 will similarly read 2Defined as the slope of the line connecting the AD594/AD595 errors measured at 0°C and 50°C ambient temperature. 3Pin 8 shorted to Pin 9. 4Current Sink Capability in single supply configuration is limited to current drawn to ground through 50 k resistor at output voltages below V. 5VS must not exceed 16.5 V.
Specifications shown in boldface are tested on all production units at final electrical test. Results from those tests are used to calculate outgoing quality levels. All min and max specifications
are guaranteed, although only those shown in boldface are tested on all production units.INTERPRETING AD594/AD595 OUTPUT VOLTAGES To achieve a temperature proportional output of 10 mV/°C and accurately compensate for the reference junction over the rated
to match the transfer characteristic of J and K type thermocouples at 25°C. For a type J output in this temperature range the is 51.70 µV/°C, while for a type is 40.44 µV/°C. The resulting gain for the 193.4 (10 mV/°C divided by 51.7 µV/°C) and for the 247.3 (10 mV/°C divided by 40.44 µV/°C). In addition, an absolute accuracy trim induces an input offset to the output amplifier characteristic 16 µV for the AD594 and 11 µV for the AD595. This offset arises because the AD595 is trimmed for 250 mV output while applying a 25°C thermocouple input.
Because a thermocouple output voltage is nonlinear with respectcompensated signal, the following transfer functions should be used to determine the actual output voltages:
AD594 output = (Type J Voltage + 16 µV) 193.4 AD595 output = (Type K Voltage + 11 µV) 247.3 or conversely:
Table I lists the ideal AD594/AD595 output voltages as a function of Celsius temperature for type J and K ANSI standard thermocouples, with the package and reference junction As is normally the case, these outputs are subject to calibration, gain and temperature sensitivity errors. Output values for intermediate temperatures can be interpolated, or calculated using the output equations and ANSI thermocouple voltage tables referred to zero degrees Celsius. Due to a slight variation in alloy content between ANSI type J and DIN FE-CUNI
Table I. Output Voltage vs. Thermocouple Temperature (Ambient +15 V)thermocouples Table I should not be used in conjunction with European standard thermocouples. Instead the transfer function given previously and a DIN thermocouple table should be used. ANSI type K and DIN NICR-NI thermocouples are composed
Figure 1. Basic Connection, Single Supply Operationof identical alloys and exhibit similar behavior. The upper temperature limits in Table I are those recommended for type J and type K thermocouples by the majority of vendors.
SINGLE AND DUAL SUPPLY CONNECTIONS The is a completely self-contained thermocouple conditioner. Using a single +5 V supply the interconnections shown in Figure 1 will provide a direct output from a type J thermocouple (AD594) or type K thermocouple (AD595) measuring from to +300°C.
Any convenient supply voltage from +30 V may be used, with self-heating errors being minimized at lower supply levels. In the single supply configuration the +5 V supply connects to Pin 11 with the V connection at Pin 7 strapped to power and signal common at Pin 4. The thermocouple wire inputs connect to Pins 1 and 14 either directly from the measuring point or through intervening connections of similar thermocouple wire type. When the alarm output at Pin 13 is not used it should be connected to common or V. The precalibrated feedback network at Pin 8 is tied to the output at Pin 9 to provide a 10 mV/°C nominal temperature transfer characteristic.
By using a wider ranging dual supply, as shown in Figure 2, the AD594/AD595 can be interfaced to thermocouples measuring both negative and extended positive temperatures.
Algún número de pieza del mismo fabricante
Misma categoría
2011 reseñas de compradores de Spain
Raphael Mayor
Length of registration:9 years
Service was great,Parts arrived when promised.If I do need parts in a future, you are on my list.Thank you
0
0
Responder0
01/09/2023
JOSE
Length of registration:3 years
Order came in time
0
0
Responder0
10/21/2022
Marco
Length of registration:3 years
excellent customer service-highly recommended.All okay. Would buy again.
0
0
Responder0
09/26/2022
Txema Arce
Length of registration:12 years
Entrega bastante rapida .Bien empaquetado
0
0
Responder0
11/02/2017
karl dungs
Length of registration:7 years
todo ok
0
0
Responder0
11/23/2016
Patxi Mugica Ramos
Length of registration:1 years
All OK
0
0
Responder0
11/09/2016
Jose M. Sanchez
Length of registration:10 years
OK
0
0
Responder0
11/03/2016
Enrique (Edificio AUDIOTEC)
Length of registration:7 years
Probados y todo ok
0
0
Responder0
10/18/2016
Florin Matei
Length of registration:7 years
es correcto.Gracias!
0
0
Responder0
10/03/2016
Manuel Segura
Length of registration:8 years
Llegada perfecta
0
0
Responder0
09/23/2016
Método de pago europeo
Método de pago asiático
Método de pago americano
Método de pago internacional
Pedido
Pago
Transporte de mercancía
Cupón Regalo/Servicio Plus
Retorno de mercancías
Normalmente se aceptan devoluciones cuando se completan dentro de los 60 días a partir de la fecha de entrega del paquete.
Defectuoso (proporcione un informe de calidad de terceros de productos no conformes)
Los gastos de devolución deben ser prepagos; No aceptaremos envíos contra reembolso.
Politica de garantía
Todas las compras de UTSOURCE tienen una política de devolución de dinero de 60 días, más una garantía de UTSOURCE de 90 días contra cualquier defecto de fabricación. Esta garantía no se aplicará a ningún artículo donde los defectos hayan sido causados por un montaje incorrecto del cliente, el incumplimiento del cliente de seguir las instrucciones, la modificación del producto , operación negligente o inadecuada.
AD595CDZ
AD595CDZ tiene varias marcas en todo el mundo que pueden tener nombres alternativos para AD595CDZ debido a diferencias o adquisiciones regionales. AD595CDZ también se conoce con los siguientes nombres:
OPCIONES DE COMPRA
Estado de existencia: 5000
Mínimo: 1
Precio Total:
Precio unitario:17.56129
UTSOURCE
País:
United States
Correo Express: (FEDEX, UPS, DHL, TNT)Envío gratuito para los primeros 0.5kg para pedidos superiores a €181.82,cargos adicionales por peso superior
JudyGerente de personalización
sales@utsource.com
(888) 766 5577
+86 15302769052
+1 (312)899-4831
(whatsapp only)
Su dedicado servicio al cliente, brindándole el mejor servicio en cualquier momento.
Detener a los expertos en producción, podemos proporcionar una gran cantidad de componentes electrónicos que se han detenido y que son difíciles de encontrar para facilitar la empresa de mantenimiento.
Reply to
submit